MIL-DTL-29396B(MC)
Classification
Examine
Defects
Major
Minor
A
B
Inside of
a. Backstitching at armpit of
354
armhole
armhole from backarm seam of
sleeve to front edge of shield
omitted.
Collar
a. Omitted.
202a
extension tab
b. Extending less than 1/2 inch
355
or more than 1 inch beyond end of
collar.
c. Felling omitted or insecure at
203a
top, back, front or bottom edge.
d. Box stitching omitted.
204a
Collar lining
a. Ends of collar lining not
205a
securely tacked.
4.4.3.5. Finished measurements. Any measurement deviating from
the nominal dimensions and tolerance specified in Table II shall
be classified as a size measurement defect. Sleeve lengths
uneven by 1/2 inch or more shall be classified as a size
measurement defect.
4.5. Tests.
4.5.1
Lacquer tests.
4.5.1.1. Liver of sulfur. The samples to be tested shall be
immersed in a two percent by weight chemically pure liver of
sulfur (potassium sulphide) water solution, at a temperature of
100°F, for not less than three minutes. The samples shall then
be removed and rinsed in warm, then cold, then hot water, after
which they shall be wiped gently in an absorbent cellulose
material or whirled to remove residual moisture, and allowed to
air dry at room temperature for a period of one hour. There
shall be no change in the appearance of the lacquered surfaces
except for a slight overall yellowing and not more than three
dark spots, each not exceeding 1/32 inch largest dimension.
4.5.1.2. Tackiness. At room temperature (60° to 80°F) press a
piece of tissue paper against the lacquered surface for 30
62