3.3.9.4. Colorfastness. The dyed slide fastener tape shall show
colorfastness to laundering equal to or better than the standard
sample when tested as specified in V-F-106. When no standard
sample is available, the tape shall show "good" colorfastness
when tested as specified in V-F-106.
3.3.10 Labels.
3.3.10.1.Combination label. Each skirt shall have a combination
identification and instruction label conforming to type VI,
classes 2 and 15 of DDD-L-20. The fastness to laundering
requirements of DDD-L-20 shall apply.
Skirt, woman's
Contract number: M67004-94-0-000 (Example)
Name of contractor:
DRY CLEAN ONLY
3.3.10.2.Size label. The size label shall conform to type VI,
class 2 of DDD-L-20 except the stock number is not required. The
inscription on the size label shall conform to MIL-STD-984; Table
II Height Ranges, Table III Body measurements for Marine Corps
and Figure 2.
3.4. Design. The skirts shall be the U.S. Marine Corps design
shown in Figures 1 and 2, ankle length, with a one piece front,
two piece back panels fully lined with slide fastener closure at
the center back and a watch pocket on the right front at the
waistband seam.
3.5. Patterns. Standard patterns will be furnished to the
contractor by the Government (see 6.3). The standard patterns
shall not be altered in any way and shall be used only as a guide
for cutting the contractor's working patterns. The contractor's
working patterns shall be identical to the standard patterns.
Standard patterns show size, seam allowances, directional lines
for cutting, and are marked or notched for proper placement and
assembly of the component parts. The patterns provide an
allowance of 3 inches for hemming the bottom of skirt.
3.5.1 Pattern parts. The skirts shall be cut from the materials
specified herein in accordance with the pattern parts indicated
below: