MIL-DTL-29479A(MC)
TABLE I.
Manufacturing requirements - Continued.
SEAM/
STCH
STCH TYPE
BOB/
NO
OPERATION
TYPE
STCH/IN
NDL
LPR
Shade marking.
2
(cont'd)
b. The use of corrosive metal
fastening devices or sew-on tickets
for shade marking is prohibited.
c. The use of ink pad numbering
machine, rubber stamp, or pencil is
acceptable provided the numbers do
not show on the outside of the slacks
and whenever possible, numbers shall
be covered by the seam allowance.
Replacement of defective components.
3
a. During the spreading, cutting and
manufacturing process, components
having material defects or damages
that are classified as defects in
MIL-STD-656 shall be removed from
production and replaced with
nondefective and properly matched
components.
4
Make darts (basic material).
The darts shall be tapered on the
inside without twists or puckers.
Thread ends at lower end of darts
shall not be trimmed closer than 1/2
inch in length. End of dart need not
be backtacked except when automatic
dart machine is used.
a. Fold and stitch back darts as
301
OSf-1
12-14
50/3
50/3
indicated by notches and marks on the
pattern. Press toward center back.
Stitch across top of dart 1/8 inch
from raw edge.
b. Fold and stitch front darts as
301
OSf-1
12-14
50/3
50/3
indicated by notches and marks on the
pattern. Press toward the center
front. Stitch across the top of dart
1/8 inch from raw edge.
5
Make darts (lining - class 2).
The darts shall be tapered on the
inside without twists or puckers.
Thread ends at lower end of darts
shall not be trimmed closer than 1/2
inch in length. End of dart need not
be backtacked except when automatic
dart machine is used.
10
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business