MIL-DTL-29478A(MC)
Manufacturing requirements - Continued.
TABLE I.
SEAM/
STCH
STCH
BOB/
NO
OPERATION
TYPE
TYPE
STCH/IN
NDL
LPR
22 Join front eyelet cover to right
front facing.
a. Position the front eyelet cover
301
SSa-1
10-14
A
A
on the outside of the right front
facing with the front and upper raw
edges of cover and facing even.
Stitch cover to facing 1/4 inch from
raw edges.
23 Seam wool facing to lining assembly.
Finished appearance. The lining
shall be carefully aligned and seamed
to the facing so that in the finished
coat, the lining shall lie smooth and
flat along the facing without
creases, bulges, overlapping of
excess material, or other defect or
distortion.
a. Position the lining on the wool
facing with the top edges even and
notches matching.
b. Seam the front edge of the lining
301
SSa-1
10-14
A
A
to the back edge of the facing 3/8
inch from the edge. The stitching
shall extend from the top edge of the
facing to approximately 1-1/4 inches
from the bottom edge of facing.
24 Serge or overedge stitch
facing-lining assembly.
Finished appearance. The overedge
stitching shall be securely caught in
the fabric.
a. Overedge stitch together the
503
EFd-1
6-10
70/2
70/2
facing-lining or seam allowance. The
or
overedge stitching shall be securely
504
caught in the fabric.
25 Sew on identification label.
Finished appearance. The
identification instruction label
shall be positioned so that in the
finished coat, the label shall be
midway between front and back edge of
the left facing, with the bottom edge
of label approximately 4 inches from
the bottom finished edge of coat.
23
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business